Loading...
HomeMy WebLinkAbout2018 Franklin @ ReserveSHEET TITLE SIGNAL NOTES SHEET NUMBER CR-205 I/R DATE DESCRIPTION ISSUE/REVISION KEY PLAN REGISTRATION CONSULTANT AECOM 10 South Jefferson Street Suite 1600 Roanoke, Virginia 24011 540.857.3100 tel www.aecom.com CLIENT CITY OF ROANOKE Office of City Engineer 215 Church Avenue, SW Room 350 Roanoke, VA 24011 PROJECT REPLACEMENT OF FRANKLIN ROAD BRIDGE OVER NORFOLK SOUTHERN RAILWAY PROJECT NUMBER 60290893 AN S I D 2 2 " x 3 4 " 0 08/25/2016 Issued for Construction SHEET TITLE SIGNAL PLAN SHEET NUMBER CR-206 I/R DATE DESCRIPTION ISSUE/REVISION 5 07/16/2018 SIGNAL CONDUIT 6 10/03/2018 ADA RAMPS KEY PLAN REGISTRATION CONSULTANT AECOM 10 South Jefferson Street Suite 1600 Roanoke, Virginia 24011 540.857.3100 tel www.aecom.com CLIENT CITY OF ROANOKE Office of City Engineer 215 Church Avenue, SW Room 350 Roanoke, VA 24011 PROJECT REPLACEMENT OF FRANKLIN ROAD BRIDGE OVER NORFOLK SOUTHERN RAILWAY PROJECT NUMBER 60290893 AN S I D 2 2 " x 3 4 " GRAPHIC SCALES 0 08/25/2016 Issued for Construction Proposed Signals (ALL DIMENSIONS ARE TO CENTER OF POLE) Signal Pole & Controller Legend JUNCTION BOX LEGEND All Junction Boxes shall conform to St'd. JB-S3 unless otherwise noted on the plans. SI G N A L 2 4 8 PHASES 2-6 FL A S H CO M B . 2 G 4 G PED 8 PED 6 NOTES: 1. BLANK BOX INDICATES RED. 2. SIGNAL TIMINGS AND CLEARANCE INTERVALS TO BE PROVIDED BY THE CITY OF ROANOKE. SI G N A L S CL R . IN T . 30"x36" R3-5LR3-5R 30"x36" R3-6L 30"x36" Proposed Signs S-1 S-2 S-3 S-4 S-5 NOTES: 1. Signs shall conform to TE-379 and the latest version of the Virginia Standard Highway Sign Book. 2. Signs S-6, S-7, S-8, S-9 shall be installed such that the arrows are parallel to the corresponding crosswalk. SIGNAL MAST ARM POLE (PF-8), TYPE IV N 3620038.2013 E 11061190.0135 18' Luminaire Arm , 45° Angle to Franklin Rd. (See Note 2) AEL Autobahn ATB2 Roadway Luminaire 80BLEDE10 MVOLT R4 with LED Photocell and full cut-off, or approved equal meeting IES design criteria. 45' Arm, 90° Angle to Franklin Rd. Signal Placements: 29', 39' Sign Placement: 13', 43' Emergency Preemption Detector/Confirmation Light: 33' 40' Arm, 0° Angle to Franklin Rd. Signal Placements: 4',16', 30' Sign Placement: 8', 12', 26' Emergency Preemption Detector/Confirmation Light: 23' SIGNAL MAST ARM POLE (PF-8), TYPE IV N 3619969.3771 E 11061255.0861 18' Luminaire Arm, 45° Angle to Franklin Rd. (See Note 2) AEL Autobahn ATB2 Roadway Luminaire 80BLEDE10 MVOLT R4 with LED Photocell and full cut-off, or approved equal meeting IES design criteria. 50' Arm, 90° Angle to Franklin Rd. Signal Placements: 33', 43', 48' Sign Placement: 17', 30' Emergency Preemption Detector/Confirmation Light: 38' 58' Arm, 0° Angle to Franklin Rd. Signal Placements: 30', 42' Sign Placement: 16', 48' Emergency Preemption Detector/Confirmation Light: 36' 2- SP-8 Pedestrian Signal Heads 2- Pedestrian Push Buttons 1- S-7 1- S-9 PEDESTAL POLE (PF-2), 8' N 3620052.8622 E 11061319.5959 PF-2 Concrete Foundation SMB-1 One Way Hanger Assembly 1-SP-8 Pedestrian Signal Head 1-Pedestrian Push button 1-S-8 PEDESTAL POLE (PF-2), 8' N 3620025.5730 E 11061188.6610 PF-2 Concrete Foundation SMB-1 One Way Hanger Assembly 1-SP-8 Pedestrian Signal Head 1-Pedestrian Push button 1-S-6 CONTROLLER CABINET AND FOUNDATION (CF-1) N 3619962.2188 E 11061266.0417 Cabinet door hinge located on right side of cabinet when facing cabinet door UPS Cabinet piggy back on left side of controller cabinet Door hinge on right side of UPS cabinet SE-5 ELECTRICAL SERVICE N 3619965.9943 E 11061273.3496 Meter and 40 Amp Circuit Breaker Disconnect Box 72" Mounting Height 02+06 (EVP-6) 04+OL-A (EVP-4) (EVP-2) 1 - 3” Conduit (Stub conduit 2' up pole) 1 - 8/3c (Power) 2 - 8/2c (Lum) 1 - #8 EGC 1 - 3" Conduit 1 - 8/3c (Power) 1 - #8 EGC 1 - 4” Conduit 1 - 8/3c (Power) 8 - 14/7c (SP-8 x4, PB x4) 8 - 14/7c (Heads 2, 4, 4A, 4B, 6, 6A, 8, 8A) 1 - #8 EGC 1 - 3” Conduit 4 - EPDC 4 - 14/2c (CL) 1 - Cat 5 Cable (VDC) 1 - #8 EGC 1 - 2” Conduit (Spare) 1 - #8 EGC 1 - 3” Bored Conduit 2 - 14/7c (Head SP-8, PB) 1 - #8 EGC 1 - 2” Bored Conduit (Spare) 1 - #8 EGC 1 - 2” Conduit 2 - 14/7c (Head SP-8, PB) 1 - #8 EGC 1 - 3” Conduit 4 - 14/7c (SP-8 x2, PB x2) 4 - 14/7c (Heads 6, 6A, 8, 8A) 1 - #8 EGC 1 - 3” Conduit 2 - EPDC 2 - 14/2c (CL) 1 - Cat 5 Cable (VDC) 1 - #8 EGC 1 - 2” Conduit (Spare) 1 - #8 EGC 1 - 2” Conduit 2 - 8/2c (LUM) 1 - #8 EGC 1 - 2” Conduit 1 - 8/2c (LUM) 1 - #8 EGC 1 - 2” Bored Conduit 1 - 8/2c (LUM) 1 - #8 EGC 1 - 2” Conduit 1 - 8/2c (LUM) 1 - #8 EGC 1 - 3” Bored Conduit 2 - 14/7c (SP-8, PB) 4 - 14/7c (Heads 2, 4, 4A, 4B) 1 - #8 EGC 1 - 3” Bored Conduit 2 - EPDC 2 - 14/2c (CL) 1 - #8 EGC 1 - 2” Bored Conduit (Spare) 1 - #8 EGC 1 - 2” Conduit 2 - 14/7c (SP-8, PB) 1 - #8 EGC 1 - 3” Conduit 4 - 14/7c (Heads 2, 4, 4A, 4B) 1 - #8 EGC 1 - 3” Conduit 2 - EPDC 2 - 14/2c (CL) 1 - #8 EGC 1 - 2” Conduit (Spare) 1 - #8 EGC Phasing Diagram Conduit & Cable Legend COLOR SEQUENCE CHART START CROSSING Watch For Vehicles DON'T START Finish Crossing If Started TIME REMAINING To Finish Crossing DON'T CROSS STEADY TIMER FLASHING PUSH BUTTON TO CROSS FRANKLIN RD. S-6 START CROSSING Watch For Vehicles DON'T START Finish Crossing If Started TIME REMAINING To Finish Crossing DON'T CROSS STEADY TIMER FLASHING PUSH BUTTON TO CROSS S-7 START CROSSING Watch For Vehicles DON'T START Finish Crossing If Started TIME REMAINING To Finish Crossing DON'T CROSS STEADY TIMER FLASHING PUSH BUTTON TO CROSS RESERVE AVE. S-8 FRANKLIN RD. PED 6 4A 6 6A G DW DW G G G Y Y DW DW W DW DW W DW DW START CROSSING Watch For Vehicles DON'T START Finish Crossing If Started TIME REMAINING To Finish Crossing DON'T CROSS STEADY TIMER FLASHING S-9 RESERVE AVE. PUSH BUTTON TO CROSS G Y NOTES: 1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UTILITIES IN THE VICINITY OF THE SIGNAL POLE FOUNDATIONS PRIOR TO DESIGN AND FABRICATION OF STRUCTURAL ELEMENTS. 2. AEP TO INSTALL LUMINAIRE HEADS. CONTRACTOR TO PULL CONDUCTOR FOR HOOKUP DURING CONSTRUCTION. 4B G G PE D 8 08 PED SPECIAL 30"x36" S-10 6 G W DW G 6 6 6 6 6 6 SE-4 Service Removed Clearview 5-W mixed-case font 18"x96" Clearview 5-W mixed-case font 18"x96" added traffic arm extension for signal head to correct line of si ht from lane lines sidewalk removed from reserve building cleanup Revised location of 360 degree Camera Head to this arm for better view push button installed on conduit mount to achieve ADA access maximum reach limit